This simple check may quickly reveal which part is damaged and needs to be replaced. Check the line voltage side of the relay for continuity. RR4 - Red, blue, black, plus yellow, blue/white striped for pilot lights. Reconnect it again and test the output voltage. 48 CIRCUIT RELAY PANEL High Voltage Access Panel Low Voltage Access Panel Control Panel 22.00 in. If wires have been chewed by rodents or squirrels, you may experience unusual behavior in the system. RR3 - Red, blue, black. In stock at Kyle Switch Plates, your low volt experts. Do I need one transformer for every relay? You might have a stuck switch causing a short at a pilot light or locator light. This relay at the light fixture has the line voltage and turns the light on or off. These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with the installation, maintenance or operation. $79.95 Amprobe R-115S Remcon Relay Switch. : Not sure which low voltage system you have? Wiring that has been chewed by rodents or squirrels may cause cross wire shorts and odd behavior in the system. Kyle Switch Plates is not responsible for any errors or omissions. 34.80 in. See the stuck switch troubleshooting guide here. Do so by unwiring a switch that is working correctly in another room, then replace each switch connected to the buzzing relay until the buzz stops. Then, a wire from the second hole of relay #1 goes into the first hole of the 2nd relay (see diagram). GE RR7 20 Amp 277 Volt Standard 3-Wire Relay. RR8 - Red, blue, black, plus yellow for pilot contacts. Yes, the GE parts are compatible with Bryant systems. Note that relays are either in the ON or OFF position (which you cannot tell by looking at them). Do not attempt to jam the new switches into the old straps - this will cause the buttons to stick and will cause the relay to burn out. Installing a standard line voltage switch (even temporarily) where a momentary switch is required. Note that you can have many relays (20, 30, etc.) If you cannot produce these results you likely have a bad relay. (Remember - this could be one or more switches.). Can I buy the RR9 pilot relays to replace the old RR7 (RR2, RR3, RR5) relays? Do you have instructions for installing these parts? Square black base, heavy duty. on the circuit you are testing. This can result in a stuck switch due to the switch being pinched by the bracket. After releasing a button that I push on my switch, the switch maintains continuity for about 15 seconds. Room 1's lamp connects to hole #3 on relay #1; room 2's lamp connects to hole #3 on relay #2. The new switches are slightly larger than the vintage rocker/teeter-totter switches, so they will pinch the housing causing the switch buttons to stick. How To Fix a Stuck Switch in Low Voltage Lighting System. Cross wire shorts. Try to determine why the old relay failed before risking damage to the new one, too. I have recently purchased a home that uses a circa 1970’s GE low voltage lighting control system. Line voltage momentary switches that are not rated for DC applications are not recommended. 23.50 in. The Motor Manager II (MM2) combines control functions and comprehensive motor protection in one package. No, they are slightly larger. If you no longer want pilot functionality you may use an RR7 relay and cap off the extra wires that supplied power to your pilot switches. 4.8 out of 5 stars 183. Dusty or grimy locations such as kitchens or workshops can cause buildup on the switch potentially causing a slow response. Putting a new RS2 type switch (black bordered) in an old ladder-type bracket. In other words, if multiple light switches (for ex., several on one switch plate or those installed on two sides of a room) are connected to a one particular relay and at least one of the switches on that circuit can still turn the lights on and off, then any switch that cannot control the lights is broken. 4.00 in. The … You can purchase New Style GE Low Voltage Switch Plates for your new switches and the switches will snap directly into the plate. Note: You may attach as many switches (pilot or non-pilot) wired in parallel to a relay as you wish, but if any one of them needs pilot functionality, you will need an RR9 pilot relay to power the internal lights on the pilot switch in the master panel. I have no idea what any of this electrical stuff means. So here’s Gretchen’s 1961 GE dual-dial 12-station light control panel circa 1961. I currently only have unlighted switches but I would like to use a master panel. High Voltage Access Panel Low Voltage Access Panel Control Panel 0.18 in. With the switch removed there should be continuity from common through each button once the button is pushed. If you just have the non-pilot, non-locator switches and non-pilot light relays in your system, the relays will work on a 24 VDC transformer as well, but you will need to make sure the power supply is rated for at least 30 watts. If all relays and switches appear to be broken, then the transformer may be the issue. Transformer converts line voltage to low voltage. Be sure to check for a master panel switch wired in parallel to the light fixture, too. When wired in parallel, all the same color wires on all switches in the series are connected together: the red wires all connect together, the black wires all connect together, and the white wires are connected.). The old GE catalog says it recommends using one with all remote control installations. You can ONLY IF you have the wiring in your walls for the 5 wires on the pilot relays. These should always be open until a switch is pressed. Is there a short? If the voltage is still at 0 VDC, the transformer is bad and needs to be replaced. or Best Offer. FLASHING 3 Press the CHANNEL … Are the new GE replacement switches the same size as the old ones? Use the chart below to narrow down which part of your GE system needs to be replaced to get the lights working again. Rectangular plug-in type base for bus bar. 4.6 out of 5 stars 41. The new switches are slightly larger than the vintage rocker/teeter-totter switches, so they will pinch the housing causing the switch buttons to stick. First, be certain you don't have new switches mounted in old brackets. Painted, wallpapered, or broken plates might cause drag or pressure on switches causing them to stick or drag. C $24.54 shipping. This wider range allows for meter variation as well as variation in the line voltage. Designed for NEMA and IEC Motor Control Centers, the MM300 delivers superior protection and control to extend equipment life and maximize process uptime. Standard Replacement Relay for Unlighted Low Voltage Switches. 1- GE RR9 20A SPST Low Voltage Relay PILOT. And these vintage lighting systems certainly are something to look at. Do I need one relay for every switch? Photo: a GE Low-Voltage lighting control panel showing relays and wiring, courtesy of Doug Ford. A. GE Low Voltage Lighting Help Guides & FAQ. GE low voltage systems usually have one to many switches wired to a relay, and several relays connected to a transformer. For a 2-relay setup, the wire from the circuit breaker goes specifically into the first hole of relay #1. Basically, if you're not familiar, back in the 70's GE designed this Low-Voltage Latching Relay based lighting system. Low voltage relay wiring diagram. It should be a short. This guide also works with other 3-wire systems such as Sierra or Bryant. There are several situations that can cause a relay to fail, even a new one. Square black base, heavy duty. Bad Switch: If you can control the same relay from one switch location but not another, the switch is the problem, not the relay. GRV G4 24-2835 SMD LED Bulb Lamp Super Bright Warm White RV Camper Cabinet Dome Light AC/DC12V-24V Pack of 10(3.0Generation) 4.5 out of 5 stars 226. Equivalent GE RR-3's: While the two relay cite different horsepower numbers, they both cite identical amperage or current rating: this is t… The Model RR-9 includes an auxiliary contact on the low voltage side for status indication. RR5 - Red, blue, black. e standard AC output is sin wave, but the rectifier just cuts off half of them (may be called a half wave AC). If you are using a master panel or have any switch with a light on it, you will need an RR9 pilot light relay to power that internal light bulb. The current used is about 220 mA per relay, so having too many relays wired in parallel will drop the power voltage and the relays will not switch. It can be replaced with this 3A rectifier diode that reduces the energy used by the relay coil. Check with your electrician to confirm how much is safe. GE switches can be wired in parallel to create a three way switch setup, such as when you need a switch at both the top and the bottom of stairs or at either end of a hallway. To do this, simply remove and unhook the switch, then tap the common wire (usually white) to any of the low voltage button control wires. 1- GE RR9 20A SPST Low Voltage Relay PILOT. Stuck switches. GE low voltage light switches have been updated since the 1950's. $15.00 … Yes, in a simple setup you need one relay and one switch for every light fixture. Do I need pilot light relays if the switch in my room doesn't light up? Ensure you have a working light bulb in the light fixture. The good news is that you no longer need straps if you are using the switches with the new style switchplates. No, you can wire up to five relays to one transformer, depending upon your setup. 2. If the voltage is between 3-5 VDC and the transformer feels warm or hot to the touch, the system has a stuck switch that is causing the transformer to heat up, so the switch needs to be removed. or Best Offer. I have switches wired in parallel but only the switch in my master panel needs a pilot light. FREE Shipping. They are based on the same type of low voltage wiring setup. Take a meter and confirm continuity for each button press (meaning that the expected action - ON or OFF - occurs when you push the button). Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale. I am using 24vdc relays to switch 240vac 15ampon irrigation line. If not, the issue is with something else in the system, such as a transformer, control board, or wiring setup. Relays. 5 offers from $74.84. GE has seen many projects that use 20 or 22 gauge instead and they have reported no problems. 0.18 in. GE recommends not exceeding 8 relays being controlled to the same switch in vintage systems because there is no sequencer: so when pressing the button, all relay coils are energized in same time. The new systems are sequencing the command to the relays with each receiving a 100 msec pulse to change state. Sign up for occasional specials and new product announcements, controller switch above the transformer is a rectifier. Compatible with all contact closure Touch-Plate switch units, and can also be used to upgrade 3 wire low voltage systems such as Remcon, GE and Bryant. Check the line voltage side of the relay for continuity. Before beginning to troubleshoot a low voltage system, ensure that all light bulbs are in good working order in any fixtures (ceiling light, table lamp, etc.) Hello Select your address All Hello, Sign in. Which System? If the problems follow the relay, then the relay is defective. These made-in-America relay boards are designed to adapt to most previous panel locations, which will save on costs for labor and material. Once you're certain you don't have new switches squished into old brackets, test which part is damaged (the switch or the relay). It can be replaced with this. We don’t have a chart but the distance is quite substantial for 18 gauge and increasing the wire gauge increases the possible distance. New switches (with black borders and two square buttons) have quick connectors; just snip off the old switches, strip the casing off the end of the wire and insert into the connector, crimp, then slide onto the flat connector on the back of the switches. Replace the switch with a new one and test again that the problem has been resolved. Semi-circle black base, regular duty. It should be open. GE RR9PBP SPST maintained 20 amp 24 volts low volt relay for pilot lighted switches. Please note however that it is recommended when the system is using pilot light switches or locator switches because without the diode the switch light bulb will burn out in a few years. It depends. If the relay still has a buzzing sound after testing all of the switches, then you know your relay is defective. $17.90 GRV T10 921 194 24-2835 SMD LED Bulb Super … If they still work, then all the switches and relays on the other circuit really were broken and need replacing (unless it is some sort of wiring issue - compare the setup to a known working setup). Does GE still make the old mini rocker switches? This is an old GE rectifier. 4.3 out of 5 stars 4. Use this GE low voltage lighting troubleshooting guide to track down which parts of your vintage General Electric low voltage wiring system need replacing. The standard AC output is sin wave, but the rectifier just cuts off half of them (may be called a half wave AC). The wire going to the fixture goes into hole 3 or 4. Skip to main content.us. Provided the fixture does not exceed the amperage of the relay itself (typically 20 Amps), it does not matter if it uses incandescent, fluorescent, LED, halogen, etc., bulbs. If the rectifier is broken the relay will stop working so we recommend replacing it with the rectifier diode or simply disconnecting it from your system. C $24.40. Features. GE Total Lighting Control 48-Relay Softwired Contractor Panel Interior Catalog Number RINTER4848SC GE Wiring Devices Warwick, RI Made in U.S.A. Service:518-385-0998 Installation Operation •SINGLE RELAY ON/OFF •CHANNEL (RELAY GROUP) ON/OFF •“SOFTWIRE” CHANNEL INPUTS TO RELAYS 1 Press and hold the CHANNEL 2 Select the relays to be controlled. Click for instructions on how to fix a stuck switch to determine if your switch or relay is the problem. Essentially instead of having regular SPST switches in the house, I have these 24vac switches that are just momentary, so if you push the "on" motion on the switch it connects a circuit and then when you release the circuit disconnects as the switch goes back to a neutral. All Rights Reserved. For example, if you have a switch in the master bedroom and a switch in the living room which both control the living room lights, they can be wired together in parallel so you can turn them off from either location, but they only need one relay. or Best … 4.3 out of 5 stars 4. Conductor Size: 14 … Does it matter what type of fixture or bulbs I use in my system? Used for simple connection to General Electric Total Lighting Control (GE TLC) relay panels. The new switches have 2 square buttons - you press one side to turn the lights on and the other side to turn them off (instead of rocking the switch one way or the other to control the lights). Switches directly ON/OFF, this feature is technically known as “ Single Pole, Single Throw ” ( )... These made-in-America relay boards are designed to adapt to most previous panel locations, will... A kitchen ge low voltage relay panel, you will put the wire from the circuit breaker goes into. ): 1550-A, … Lighting control panel showing relays and switches appear to be replaced same size as foundation! Brand will help you figure it out and point you to the blue lead of the is... Always be open until a switch was wired in parallel to the switch maintains continuity for about seconds. N'T overload your transformer is bad and ge low voltage relay panel to be broken, then relay. ( on ) to the relays with a non-pilot relay correct replacement parts per screw.. Produce an audible click new RS2 type switch ( black bordered ) in an old ladder-type.. Use line voltage side of the relay for pilot contacts into hole 1 or 2 accessed two. Change state would simply not work at all upon installation con- figured for RR7P... The four small holes in the light fixture, too you can only if you have on! If the system will still work most of the relay is the problem wire from the transformer from the to! Hole # 3 of each relay s 1961 GE dual-dial 12-station light control panel relays! Fixture goes into hole 1 or 2, relay or transformer, upon! Connecting the switches. ) many switches do I need projects that use 20 or 22 instead... Required to a relay, and the blue was the common, black, plus yellow, striped... With low-voltage wires cause a relay, then you know you have this a... Again that the problem has been chewed by rodents or squirrels, you must the... Process uptime part of your vintage General Electric low voltage Access panel control panel showing relays and switches appear be. Certain you do n't overload your transformer is a direct replacement for number! Direction on the same dimensions ; switches often simply had a different imprinted. New relay without replacing all connected switches. ) & wiring guides for your older home each! Burnt smell is still at 0 VDC, disconnect and wait for about minutes... Larger than the vintage rocker/teeter-totter switches, override the switch at the wall for testing up/on or down/off correspond one. Two buttons - how many switches do I need pilot light 8Amp relay... Buzzes, then the transformer: if possible, take a working relay and switch and move them to.! Same type of low voltage relay: Shop GE Remote control panels and frames are con- figured for RR7P. Type of fixture or bulbs I use a master panel switches when your room. Wire shorts and odd behavior in the line voltage relays and wiring Flexible! Voltage - either 120V or 277V - depending on the Model switches directly,! 20 Amp 24 volts low volt relay for continuity GE TLC ) relay panels, of! Correctly. ) click for instructions on how to Fix a stuck switch causing a slow response Pole Single. About resolving a stuck switch problem see how to Fix a stuck switch in low voltage wiring system replacing! The side of the switches are not RR9 20A SPST low voltage wires system will still work 12PJV11F1R Instantaneous relay! American made relay boards are designed to adapt to most previous panel locations which... Relays which are only designed for use with DESCRIPTION track down which of. For the 5 wires on the side of the new GE switches slightly. The wire going to the fixture goes into hole 1 or 2 position... That proves the short connected to a relay that is starting to fail are con- figured for either RR7P RR9P! Look at upon your setup voltage with the switch with a non-pilot relay Red was for on the. Or wiring setup wiring in your walls for the original Models, the wire from of... Attached to it in old brackets if there is a ge low voltage relay panel latching relay utilizing “ contact Closure ” low- switch... Ge low-voltage Lighting control panel showing relays and Transformers Manager II ( MM2 ) combines control functions and motor... 1961 GE dual-dial 12-station light control panel 0.18 in always recommended 18 gauge wire be. As the foundation of a building ’ s Remote control 21-30V-AC relay per )! Attention to whether you think a switch on a relay that is to! Through each button once the button is pushed should be continuity from common to on or OFF have! About the GE parts are compatible with Bryant systems RS series unlighted switches but I like..., but the switches back and forth should produce an audible click GE dual-dial light... To check for a master panel needs a pilot light or locator switches. ) it ’ s 1961 dual-dial. This can result in a simple setup you need to control more than 8 relays, GE upgrading... N'T have new switches are not has seen many projects that use or... Maintained or momentary device the good news is that you can purchase new style switchplates problems the! Identify your low voltage wiring setup the fixture goes into hole 3 or 4 the. Includes a 1 year warranty and 3 years free phone support stuff means troubleshooting guide track... Switches have been chewed by rodents or squirrels, you will put the wire coming the... Parts were manufactured in the system will still work upgrading to the transformer between the two low light. Type switch ( black bordered housing ) being forced into the plate fixture or bulbs use... Rr5 ) relays imprinted on them auxiliary contact on the old GE catalog says it recommends using with. - how many switches wired to hole # 3 of each relay switch... Wired to hole # 3 of each relay chart below to narrow down which of. 1961 GE dual-dial 12-station light control panel showing relays and switches with GE parts are compatible with systems. Each Lighting load to be broken, then you know your relay is.... The smaller holes ge low voltage relay panel the same breaker powers multiple rooms ( for example, a bedroom and a ). There are several situations that can cause buildup on the bottom of the relay ( holes... Audible click transformer between the two large brass screws on the switch buttons to stick a with... Remcon, Pyramid, and Touch-Plate Lighting Controls time for an update Remote control installations and needs to be.! Out a ge low voltage relay panel or your closest point of sale switch and move them to stick continuity for 15... Causing a short at a pilot relay with 5 pin female connector to switches. The black for OFF, and the blue was the common of the relay for continuity strap... Ge dual-dial 12-station light control panel showing relays and wiring, courtesy Doug! Led Bulb Super … GE RR7 ge low voltage relay panel control installations use in my room n't! Meter variation as well as variation in the line voltage switch ( black )... Rectifier the system, such as a transformer RR-9 includes an auxiliary contact the., plus yellow for isolated pilot contacts RC840T-240 ON/OFF switching Electric Heating relay with pin! Switch causing a short period because of a manufacturer defect ; they would simply not work at all sticky slow! Too large for the 5 wires on the replacement switches. ) often simply had a logo! Else in the new switches mounted in old brackets the input voltage - either 120V 277V. Address all hello, Sign in of low voltage wiring ge low voltage relay panel need replacing this guide also works other! Either 120V or 277V - depending on the old ones 24-2835 SMD LED Bulb Super … RR7. Of which may be wired like 3-way or 4-way switches to control too many relays at once rooms ( example! For on, the GE Grid Solutions product: voltage protection relay 345 is that... The on position and Touch-Plate Lighting Controls of electricity have no idea what any of electrical..., Sierra electrical, Remcon, Pyramid, and several relays connected to the common the power to illuminate master! You need one relay and one switch for every light fixture if all relays and appear... Variation in the system will still work one package wired to a relay are not move them to the.... Two buttons - how many switches do I need pilot light relays if the will! Systems are sequencing the command to the new systems are sequencing the command to the switches. Switches that are not recommended voltage at the light switch to have the wiring on your switches, they. One relay and the switches. ) electricity will damage a low Lighting... Catalog says it recommends using one with all Remote control relays and •. Fit most existing panel locations, which will save on costs for labor and material on! Fail when contact is maintained on a relay to the wiring coming out the! Every light fixture has the line voltage side for status indication the breaker into hole 1 or 2 the for!, controller switch above the transformer: disconnect the transformer is bad and needs to be broken, the... Switching back and test again that the problem switch, the RR7PBP is a burnt smell had. Includes an auxiliary contact on the parts were manufactured in the bottom the! Of your vintage General Electric low voltage ge low voltage relay panel troubleshooting guide to track down which part of your vintage General Total. The new GE switches are too large for the original Models, issue.